Item Description
1 Buffer/barrier fluid IN (G1/2")
2 Buffer/barrier fluid OUT (G1/2")
3 Cooling water IN (G1/2")
4 Cooling water OUT (G1/2")
5 Filling connection with plug 1(G1/2")
6 Pressure gas connection (G1/2")
7 Connection for level switch or level indicator (G2")
8 Connection for refill unit (G1/8")
9 Universal connection (G1/2" for safety valve, flare, etc.)
10 Bracket for refill unit
11 Sight-glass

TS4000

Features

With the EagleBurgmann gap-free executed TS4000 thermosiphon system it is possible to supply buffer/barrier fluid to double and tandem mechanical seals for a broad range of applications. The range is available in completely gap-free design with torispherical heads, sight-glass for level monitoring and with cooling coil. TS vessels are equipped as standard with all the necessary system connections and brackets.

Circulation based on API 682 / ISO 21049: Plan 52, Plan 53A

Advantages

  • Gap-free design; pickled and passivated surface inside and outside
  • Suitable for a wide range of demanding operating conditions: TS4030 up to 30 bar / 200°C
  • Cooling water connections at top (OUT) and bottom (IN): optimum draining and venting
  • Sockets with recessed gasket: no contamination of the circuit by thread sealant

Standards and approvals

  • PED 2014/68/EU (Design and production in accordance with EU Pressure Equipment Directive)
  • Compliant to TA Luft (German Clean Air Act)

Functional description

The TS system performs all the basic functions of a buffer/barrier system for the operation of double seals:
  • to pressurize the buffer chamber
  • leakage compensation
  • buffer/barrier fluid is circulated by thermosiphon effect or external circulation system
  • to cool the seal
  • to selectively absorb product leakage and prevent dry running (tandem arrangement)

Use compressed air or nitrogen for pressurization.

Notes

The modular system allows the TS4000 vessels to be combined with a wide range of system components such as, e.g. level switch, circulation pump, hand refill pump, thermometer, etc.



Product variants

Designation TS4030/A002
Design code PED 2014/68/EU
Integrated cooling coil
Volume, vessel (liters) 9
Volume, tube (liters) 0.5
Allowable pressure1) 30 bar
(435 PSI)
Allowable temperature1) -60 °C ... +200 °C
(-76 °F ... +392 °F)
Working volume, MAX-MIN (liters) 1.8
Cooling capacity –
natural circulation (kW)2)
1.5
Cooling capacity –
forced circulation (kW)2)
4.0
Metal parts 1.4571
Sight-glass Reflex Borosilicate
Seal PTFE

Other versions on request.

1) Design data, permissible working values depend on the actual conditions of service.
2) The cooling performance depends on the available fluids, their temperatures and flow rates. Please contact EagleBurgmann for professionally selecting the correct heat exchanger.

Similar products

TS1000

With the EagleBurgmann TS1016 thermosiphon system it is possible to supply buffer/barrier fluid to double and tandem mechanical seals for a broad range of applications. The TS1016 thermosiphon vessel is available in 2 standard sizes with flat ends, sight-glasses for level monitoring and with or without cooling coil. TS vessels are equipped as standard with all the necessary system connections and brackets. The modular system allows the TS1016 vessels to be combined with a wide range of system components such as, e.g. level switch, circulation pump, hand refill pump, thermometer, base frame, etc.

Circulation based on API 682 / ISO 21 049: Plan 52, Plan 53A

TS3000

Thermosiphon systems of the TS3000 range designed specifically for the operation and supply of mechanical seals in sterile processes. The TS3000 thermosiphon vessel is available in two standard sizes, designed for dismantling, with cooling coil. The modular system allows the TS3000 vessels to be combined with a wide range of system components.

Circulation based on API 682 / ISO 21 049: Plan 52, Plan 53A

TS3016

The EagleBurgmann TS3016 thermosiphon system presents a simple and quick way to clean the vessel interior. For this purpose it is designed for easy dismantling. A quick-release coupling should therefore be used to connect the pressure gas to the vessel. The modular system allows the TS3016 vessels to be combined with a wide range of system components.

Circulation based on API 682 / ISO 21049: Plan 52, Plan 53A
Contact

Inquire about individual solutions

We develop and produce customer-specific special and individual solutions for every application.

Inquire now Discover reference projects
Back to the overview